May 2009 AfiFree Terminal 155i Installation Manual 79
Pressing "Code"+"8" returns the milk flow to the main milk line.
This feature is useful if a milker notices that here is some blood in the milk.
Automatic Milk Diversion
This feature automatically diverts milk from an animal that has been identified with a
health code. The duration of the milk diversion depends on the code assigned to the
animal:
If the animal has assigned a Dump Milk Operation code, milk is diverted
throughout the milking.
If the animal has assigned a Dump First Milk Operation code (DPM parameter),
only first milk is diverted.
Milk Remainder
(either under AfiSheep/ AfiGoat or in a standalone configuration)
A certain amount of milk remains in the bend of the tube after the animal is milked.
When milking resumes, this milk passes through the AfiFree155 body too quickly to
be registered. The Milk Remainder parameter compensates by automatically adding a
set amount to the quantity of milk recorded for each animal.
Sweep
(either under AfiSheep/ AfiGoat or in a standalone configuration)
AfiFree 155i milk meters can be set to remove milk remaining in the milking tube
after each milking by performing a sweep. The sweep pulse duration, number of
sweep pulses, and sweep delay can be set individually in three parameters with those
names (see Table 19).
Viewing software version
(either under AfiSheep/ AfiGoat or in a standalone configuration)
These options enable you to view the software versions, as follows;
Terminal 155i: Press buttons "F"+"0" simultaneously.
Milk Meter: Press buttons "Stall number"+"0" simultaneously.
Setting Parameters in AfiSheep/ AfiGoat
Group Retrieval
If you want to raise or lower clusters in groups, you need to set two parameters in the
AfiSheep/ AfiGoat real-time window:
Set Lowering Clusters in Batches Number of Milk Meters per Batch to a value
of at least 1.
Allow Remote Parlor Operations (1-enable, 0-disable) to 1.